PATENTS PENDING
32
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
HEX
NUT
2 GA
TERMINAL
LUG
FIG. 32-1
4. Cut any excess wire from long power cable.
Strip 1/2” insulation from the cut end and
install 2 GA terminal lug and shrink tubing.
Next, insert the power cable through the
protective cover (FIG. 32-1). Connect the
cable terminal to the terminal stud on the
dc relay as shown in FIG. 32-1. Position the
protective cover over the power cable con-
nection (FIG. 32-1).
5. Route the interlock cable from safety interlock sys-
tem on the vehicle, underneath vehicle fl oor and
through the grommet, and up to the Lift (FIG. 32-2).
If possible, use the same cable routing as the long
power cable installed in previous steps.
Secure the interlock cable every 8”-10”.
6. Make sure interlock cable will reach
the white-red stripe wire (interlock
signal from vehicle) and the brown
wire (interlock signal to vehicle) on
the Lift (FIG. 32-2). Signal may be
ground or V+. Connect the interlock
wires from the vehicle interlock sys-
tem to the white-red stripe wire and
brown wire on the Lift (FIG. 32-2).
FIG. 32-2
INTERLOCK WIRE
(SIGNAL FROM
VEHICLE)
BROWN WIRE
(FROM LIFT)
WHITE-RED STRIPE
WIRE (FROM LIFT)
INTERLOCK
CABLE
INTERLOCK WIRE
(SIGNAL TO
VEHICLE)
ROUTE/CONNECT CABLES & HAND PENDANT - Continued
LONG
POWER
CABLE
EXTERNAL
TOOTH LOCK
WASHER
TERMINAL
STUD
DC RELAY